Moisture Analyzers Easy To Operate, Accurate Measurement
Oct 09, 2017

Moisture Analyzers is a new type of rapid moisture detection equipment, sub-detection equipment. The ring-shaped halogen lamp ensures that the sample is uniformly heated, that the operation is simple and accurate. Halogen Moisture Analyzers At the same time as the weight of the sample, the Halogen Moisture Analyzers uses a circular tube halogen heating method to quickly dry the sample. During the drying process, the moisture meter continuously measures and instantly displays the moisture content of the sample. After the drying process is completed, The measured moisture content value is locked.

In the use of rapid Moisture Analyzers to use your fingers to tap the button, to avoid the use of nails, but also prohibit the use of sharp hard objects.

Fast water detector cover to lightly put.

The minimum sample size must be greater than 0.5 grams.

When the rapid Moisture Analyzers is in the standby state, no need to warm up to use.

The rapid Moisture Analyzers should clean the sample tray before placing the sample, and whenever the sample tray holder should be used to prevent the hot sample plate from burning.

The last display state of the test will be retained on the screen until you press the peel key. The second subsequent test should be as soon as possible to prevent the loss of moisture.

Before using the halogen Moisture Analyzers carefully check the power supply voltage and halogen Moisture Analyzers requirements are consistent, socket and equipment plug is intact, if damaged do not use. Before get off work or for a long time do not use the instrument, please turn off the total power switch, no main switch to plug the power plug placed next to the instrument.

For the sale of a variety of Karl Fischer volumetric Moisture Analyzers, the proposed flexible packaging manufacturers according to the price list, choose to pay attention to the following points:

1, the best choice when considering automatic instrument. The manual Moisture Analyzers requires the tester to visually examine the reagents in the glass burette and to manually shut down after reaching the end point, resulting in unnecessary errors due to the different movements of each person.

2, the choice should be considered to buy a fully enclosed test system. Exposed Karl Fischer reagent because of the presence of iodine, very easy to absorb moisture, the measured ethyl ester samples and methanol solvent should also try to avoid the air into the water and the error situation.

3, should consider the life of the metering pump. Metering pumps are a key part of the Moisture Moisture Meter. The Karl Fischer reagent is a highly corrosive reagent. It should be purchased with a metering pump made of corrosion-resistant materials such as fluoroplastics to prevent leakage. scrapped.

4, electrode problems. This part belongs to the core part of the instrument, on the one hand should have a high sensitivity, on the other hand, because of its test soak in the test tank, the best choice with high quality platinum electrode equipment to maintain electrode life.